RHEONIK RHM-80 SERIES - CORIOLIS MASS FLOW METER

 

Rheonik Coriolis Mass Flowmeter RHM-80 Series- Large Coriolis Mass Flowmeter

The RHM 80 can measure fow rates up to 480 t/h (17,637 lb/min) with temperatures in excess of 280°C and pressures up to 198 bar. This large sized model is also appropriate for tough application conditions,
manufactured by GE’s Rheonik mass fowmeter experts

Rheonik Coriolis Mass Flow Meter RHM80

.

Applications
• Loading of boats, vessels, rail tank wagons
• High temperatures and other challenging applications
• Highly viscous media (low pressure drop and excellent performance at low flow conditions)

Features
• Suitable for pressure up to 198 bar
• Flow uncertainty down to 0.15%
• Density uncertainty down to 0.5%
• Repeatability better than 0.05%
• Unique torsion oscillator
• Typical measuring ranges from 200 to 8000 kg/min
• Minimal fows as low as 130 kg/min
• Customization possible
• Hazardous Area Approvals (ATEX, CSA,...)

Advantages
• High fow rates for fast flling, in combination with high operating pressure
• Torsion oscillator design assures most stable and basically drift free measurement and increased signal to noise ratio
• Not sensitive to changes in pressure
• Longest life time and increased safety (low stress in welds and increased wall thickness against abrasion)
• No moving parts, practically no maintenance

Temperature Range
• NT Models from -20 to +120°C (-4 to +248°F)
• ET Models from -45 to +120°C (-49 to +248°F)
• ET2 Models from -45 to +210°C (-49 to +410°F)
• ET1 Models from -196 to +50°C (-320 to +122°F)
• HT Models from 0 to 350°C (+32 to +662°F)
(Heating for housing optional, please consult your local agent)

Electrical Connection
• Junction box Aluminium coated (standard). Junction box in SS 316Ti optional
• Cable entry M25 x 1.5. Optional cable entries M20 x 1.5, 1/2” NPT or 3/4” NPT
• Max cable length between RHM and RHE is 100m (330 ft). 200m (660 ft) only with factory approval

Material of Wetted Parts
• 1.4571 / SS 316 Ti / UNS S31635 (standard)
• 2.4602 / Alloy C22 / UNS N06022
• 1.4462/Duplex/UNS S31803
• Others on request

Sensor Enclosure/Housing
• Stainless Steel 1.4301 / SS 304, optional in 1.4571 / SS 316Ti. Others on request
• Protection Class IP 65. Optional IP 66 / NEMA 4x

Approvals
• ATEX Ex II 1 G, EEx ia IIC T6-T1
• CSA USA-Canada, Class I, Div. 1, Groups A, B, C, D
• PED according to directive 97/23/EC:, Module B + C1
• Others on request

Rheonik Coriolis Mass Flow Meter RHM80 Dimension A2 = 1320 mm (51.97 in)
H1 = 1505 mm (59.25 in)
B2 = 403 mm (15.87 in)
H2 = 1775 mm (69.88 in)
W = 150 mm (5.91 in)

 

 
Connection
Face to Face Length (L)
 
mm
inch
Standard Flange DIN DN150/PN16
Flange DIN DN150/PN40
Flange ANSI 6" 150# RF/SF
Flange ANSI 6" 300# RF/SF
Flange ANSI 6" 600# RF/SF (*)
900
900
900
900
900
35.43
35.43
35.43
35.43
35.43
Optional Flange DIN DN150/PN100 (*)
Flange DIN DN200/PN16
Flange ANSI 6" 900# RF/SF (*)
Flange ANSI 6" 900# RTJ (*)
Flange ANSI 6" 1500# RF/SF (*)
Flange ANSI 6" 1500# RTJ (*)
Flange ANSI 6" 2500# RTJ (*)
Flange ANSI 8" 300# RF/SF
Flange ANSI 10" 300# RF/SF
Flange JIS RF 10k 150A (6")
Flange JIS RF 20k 150A (6")
900
900
900
900
900
900
900
900
900
900
900
35.43
35.43
35.43
35.43
35.43
35.43
35.43
35.43
35.43
35.43
35.43

 

 

Back to previous page (Kembali ke halaman sebelumnya)