SAGE PRIME SIP INLINE MODEL - THERMAL MASS FLOW METER - SAGE METERING

 

GENERAL INFORMATION

STYLE : Integral In-Line Mass Flow Meter
SENSOR : Two reference grade platinum RTD clad in 316SS (1.4401) sheath
MATERIAL : Wetted metal components: 316SS
POWER : 24VDC Standard (115/230VAC optional)
POWER DISSIPATION : <2.5 W (for 24VDC Models)
ELECTRONICS : Microprocessor based (Hybrid-Digital)
ELECTRONICS ENCLOSURE : Zone 1, Group IIB+H2, IP66 Class III, Type 4X - Class 1, Zone 1, Groups IIB+H2, IP66
DISPLAY: High contrast photo-emissive OLED graphical display (Flow Rate, Totalizer, Temperature
TURNDOWN : 100 to 1
RESOLUTION: 100 to 1
LOW END SENSITIVITY: 25 mm/sec (5 SFPM)
FIELD CALIBRATION CHECK: Yes - Digital system allows raw signal validation in milliwatts (In-Situ Calibration Check)
COMMUNICATIONS: Modbus® compliant RS485 RTU or optional HART® communications
APPROVALS: CSA C22.2 (24 VDC); ULI604, Class I, Div 2, Groups B, C, D T4 (24VDC);
CE (AC Power or 24VDC)
FIELD RECONFIGURABLE: Sage ADDRESSER required
FLOW ACCURACY: +/- 0.5% of Full Scale +/- 1% of reading (Enhanced accuracy optionally available with limited turn-down)
FLOW REPEATABILITY: 0.2%
RESPONSE TIME: 1 second time constant
GAS TEMPERATURE RANGE: -40° to 200°F (93°C), Optional to 300°F (149°C) and 450°F (232°C)
GAS PRESSURE: 34 Bar (500 PSIG) (If higher pressure needed, contact Sage)
FLOW OUTPUT: 4 to 20 mA for Rate
TOTALIZER: 24VDC pulse for Totalized value
TEMPERATURE OUTPUT: Through Modbus® only
AMBIENT TEMPERATURE: -40° to 150°F (66°C)
FLOW BODY: 316SS Schedule 40 Flow Bodies sized from 1/4" x 6" long to 4" x 12" long.
Male NPT ends standard (Flanges and other options available)
FLOW CONDITIONING: Flow Conditioners are built in to In-Line Style Flow Bodies from 1/2" to 4"
ENCLOSURE DEPTH: DC: 4.35" ; AC: 5.35"

 

.WIRING CONNECTION ACCORDING FROM SUPPLIED POWER

24 VDC POWER SUPPLY

Sage Prime SIP Inline Wiring 24VDC

 

 

 

 

 

 

 

 

 

 

115 VAC OR 230 VAC POWER SUPPLY

Sage Prime SIP Inline Wiring 115-230VAC

 

PRODUCT RANGE

SAGE PRIME SIP INLINE WITH NPT MOUNTING CONNECTION

Sage Prime SIP Inline NPT Dimension

 