• Seametrics Flow Meter
  • Site Lab Ultrasonic Flow Meter
  • Siargo Gas Mass Flow Meter
  • VSE Positive Displacement Flow Meter
  • Tek Air HVAC Air Flow Meter
  • Gerand Fire Pump Test Flow Meter
  • Nanabosh Electrical Circular Connector
  • Sibas Heavy Duty Electrical Rectangular Connector
  • Daiwa Dengyo Electrical Safety Plug Connector
  • Gast Pneumatic Air Motor
  • Mecon Flow Meter
  • Rheonik Coriolis Mass Flow Meter
  • Sage Metering Thermal Mass Flow Meter
 

  • WIRATAMA MITRA ABADI
  • PHONE : ++62-851-0301-9945, +62-851-0506-2090, +62-812-8208-4779
  • FAX : +62-21-8855857
  • E-MAIL : sales@wmablog.com
  • CONTACT : Ira, Kusuma Dewi, Yati, Yugo

 

SAGE PRIME SERIES - THERMAL MASS FLOW METER - SAGE METERING

 

SAGE PRIME™ THERMAL MASS FLOW METER FOR GASES


Sage Prime is the top selling meter in our Product Line. The Sage Prime Thermal Mass Flow Meter features a bright, high contrast, photo-emissive OLED (Organic LED) display of Flow Rate, Total and Temperature in a robust, yet lightweight, dual-sided NEMA 4 enclosure. The Flow Rate is also displayed graphically in a horizontal bargraph format. The rear compartment is completely separated fromthe electronics, and has large, easy-to-access, well marked terminals, for ease of customer wiring (see photo below). It is powered by 24
VDC (12 VDC optional, or 115/230 VAC). The power dissipation is under 2.5 watts (e.g. under 100 mA at 24 VDC).
The Sage Prime Flow Meter is offered in Integral or Remote Style (which has Lead-Length Compensation up to 1000 feet as well as an Explosion Proof Junction Box). Specify any standard probe length or flow body size. It has a 4-20 mA output as well as a pulsed output of Totalized Flow (solid state transistor drive). In addition, Sage Prime supports full Modbus® compliant RS485 RTU communi cations (IEEE 32 Bit Floating Point).
Sage Prime is CE approved, and CSA, UL approved for Hazardous Service1 (see “Approvals”under the “Technology” tab on the website). For ATEX Zone I approvals, request Sage Rio Flyer (SIX Series).

MAJOR BENEFITS OF THERMAL MASS FLOW METERS

.- Direct Mass Flow No need for separate temperature or pressure transmitters
- High Accuracy and Repeatability Precision measurement and extraordinary repeatability
- Turndown of 100 to 1 and resolution as much as 1000 to 1
- Low-End Sensitivity – Measures as low as 5 SFPM (e.g., 1 SCFM in a 6" pipe)
- Negligible Pressure Drop – Will not impede the flow or waste energy
- No Moving Parts – Eliminates costly bearing replacements, and
prevents undetected accuracy shifts
- Dirt Insensitive – Provides sustained performance
- Ease of installation and convenient mounting hardware

SPECIFIC BENEFITS OF THE SAGE PRIME
- Features In-Situ “Field Zero Calibration Check” of sensor’s performance verifies that the sensor is clean, and assures that there is no drift, or shift in the flow meter
- Compact design of enclosure is only 41⁄ 8" dia. by 41⁄ 4" deep (DC Models
- High contrast photo-emissive OLED display with numerical FlowRate, Total and Temperature, as well as Graphical Flow Indicator
- Calibration milliwatts (mw) is continuously displayed, providing for ongoing diagnostics
- Photocell activated Screen Saver to extend display life
- Proprietary digital sensor drive circuit provides enhanced signal stability and unaffected by process temperature & pressure changes
- Modbus® compliant RS485 RTU communications (HART™ optional)3
- Isolated 4-20 mA output and pulsed output of Totalized Flow
- Rugged, user-friendly packaging with easy terminal access
- Option for Solar Energy use (12VDC models)
- Remote Style has Lead-Length Compensation. Allows remote electronics up to 1000 feet from probe; Explosion Proof Junction Box has no circuitry, just terminals (suitable for harsh environments)
- Low power dissipation, under 2.5 Watts (e.g. under 100 ma at 24 VDC
- Field reconfigurability via optional Addresser software
- Flow conditioning built into In-Line flow meters (1/2" and up)
- Captive Flow Conditioners for Insertion meter applications, if required

GENERAL INFORMATION

Standard accuracy is +/– 0.5% of Full Scale +/– 1% of reading with a turn down of 100 to 1 and resolution as much as 1000 to 1. Repeatability is 0.2%.
NOTE: Enhanced accuracy optionally available with limited turn-down


.The electronics has an isolated 4 to 20 mA output proportional to Mass Flow Rate as well as pulsed outputs of Totalized Flow (24 VDC solid state transistor drive). In addition, Modbus RS485 RTU communications is standard (IEEE 32 Bit Floating Pt).

INTEGRAL STYLE ELECTRONICS
Electronics is Integral Style, with rugged windowed dual compartment NEMA 4 enclosure with local display. The display is a high contrast photo-emissive OLED display with Screen Saver , and it displays
Mass Flow Rate, Totalized Flow and Temperature as well as a graphical representation of Flow Rate in a horizontal bar graph format. In addition, the calibration milliwatts (mw) is continuously displayed, providing ongoing diagnostics.

REMOTE STYLE ELECTRONICS

Electronics is Remote Style, with rugged windowed dual compartment NEMA 4 enclosure with display. The display is a high contrast photoemissive OLED display with Screen Saver , and it displays Mass Flow Rate, Totalized Flow and Temperature as well as a graphical representation of Flow Rate in a horizontal bar graph format. In addition, the calibration milliwatts (mw) is continuously displayed, providing ongoing diagnostics. Includes Remote Mounting Hardware.
The Flow Element’s Junction Box is Explosion Proof (Class 1, Div 1, Groups B, C, D), and does not have any electronics – only a wiring terminal block. The Junction Box is connected to the Remote Electronics by 25 feet of lead-length compensated cable. The cable (6-conductor) can be lengthened or shortened without affecting accuracy (max loop resistance 10 ohms, over 1000 feet), if grounded properly.

 

MODEL / TYPE OF SAGE PRIME SERIES

COMPACT / INTEGRAL MODELS

Sage Prime SIP Insertion Sage Prime SIP Inline

 

REMOTE / SEPARATE MODELS

Sage Prime SRP Insertion Sage Prime SRP Inline

 

 

Back to previous page (Kembali ke halaman sebelumnya)