SAGE RIO SERIES - THERMAL MASS FLOW METER - SAGE METERING

 

SAGE RIO THERMAL MASS FLOW METER FOR GASES

The Sage Rio Thermal Mass Flow Meter provides the same levels of
performance found in the popular Sage Prime with the added ATEX
Zone 1 Flame proof approvals. The Rio features a bright, high contrast,photo-emissive OLED (Organic LED) display of Flow Rate, Total and Temperature in an explosion proof, dual-sided NEMA 4X enclosure.
The Flow Rate is also displayed graphically in a horizontal bar
graph format. The rear compartment is completely separated from the electronics,and has large,easy-to-access,well marked terminals,for ease of customer wiring. It is powered by 24 VDC (115/230 VAC optional). The power dissipation is under 2.5 watts (e.g. under 100 mA at 24 VDC).Standard outputs include 4–20mA, pulsed out-puts of totalized flow and full Modbus compliant RS485 RTU communications or optional HART communication1
Sage Rio is Zone 1 approved: II 2G Ex d IIB+H2 T6 Gb.T6 Rating is suitable for gases with ignition temperature aslow as 185°F (85°C).

MAJOR BENEFITS OF THERMAL MASS FLOW METERS
- Direct Mass Flow – No need for separate temperature or pressure transmitters
- High Accuracy and Repeatability – Precision measurement and extra ordinary repeatability
- Turndown of 100 to 1 and resolution as much as 1000 to 1
- Low-End Sensitivity – Measures as low as 5 SFPM (e.g., 1 SCFM in a 6" pipe)

SPECIFIC BENEFITS OF THE SAGE RIO
- Features In-Situ “Field Zero Calibration Check” of sensor’s performance – verifies that the sensor is clean, and assures that there is no drift, or shift in the flow meter
- ATEX Zone 1 Approval with T6 Rating suitable for gases with ignition temperature as low as 185°F (85°C).
- High contrast photo-emissive OLED display with numerical Flow Rate, Total and Temperature, as well as Graphical Flow Indicator
- Calibration milliwatts (mw) is continuously displayed, providing for ongoing diagnostics
- Photocell activated Screen Saver to extend display life2
- Proprietary hybrid-digital sensor drive circuit provides enhanced signal stability and unaffected by process temperature and pressure changes
- Modbus® compliant RS485 RTU communications (HART optional)
- Isolated 4-20 mA output and pulsed output of Totalized Flow
- Heavy industrial packaging with easy terminal access
- Optional Remote Style with Lead-Length Compensation. Allows remote electronics up to 1000 feet from probe; Explosion Proof Junction Box has no circuitry, just terminals (suitable for harsh environments)
- Low power dissipation, under 2.5 Watts (e.g. under 100 ma at 24 VDC)
- Field reconfigurability via optional Addresser software
- Flow conditioning built into In-Line flow meters (1/2" and up)
- Captive Flow Conditioners for Insertion meter applications, if required

GENERAL INFORMATION

SENSOR : Two reference grade Platinum RTDs clad in 316SS sheath
MATERIAL : Welted metal components: 316SS
POWER : 24VDC Standard (115/230VAC optional)
POWER DISSIPATION : <2.5 w (for 24VDC Models)
ELECTRONICS : Microprocessor based
ELECTRONICS ENCLOSURE : Integral mount, Explosion Proof , Class I, Zone 1,Groups B,C,D,Type 4X
DISPLAY : High contrast photo-emissive OLED graphical display (Flow Rate,Totalizer,Temperature)
TURNDOWN : 100 to 1
RESOLUTION : 1000 to 1
LOW END SENSITIVITY : 5 SFPM
FIELD CALIBRATION CHECK : Yes – Digital system allows raw signal validation in milliwatts (In-Situ Calibration Check)
COMMUNICATIONS : Modbus® compliant RS485 RTU communications
APPROVALS : ATEX Zone 1-II 2 G Ex d IIB+H2 T6 Gb
Note: T6 Rating is suitable for gases with ignition temperatures as low as 185˚F (85˚C)
FIELD RECONFIGURABLE : Yes –Sage Addresser or Sage Dongle
FLOW ACCURACY : ±0.5% of Full Scale ±1% of reading. (Enhanced accuracy optionally available with limited turn-down)
FLOW REPEATABILITY : 0.2%
RESPONSE TIME : 1 second
GAS TEMPERATURE RANGE : –40˚ to 200˚F (93˚C) Standard. (For higher temperature options, contact Sage)
GAS PRESSURE : 500 PSIG. (If higher pressure needed,contact Sage)
TEMPERATURE OUTPUT : Through Modbus® only
AMBIENT TEMPERATURE : –40˚F (–40˚C) to 122˚F (50˚C) for ATEX Rating

.MODEL / TYPE OF SAGE RIO SERIES

COMPACT / INTEGRAL MODELS

Sage Rio SIX Inserion Sage Rio SIX Inline Flange

 

REMOTE / SEPARATE MODELS

Sage Rio SRX Inserion Sage Rio SRX Inline

 

 

 